Fujikura FSM-60S Fusion Splicer |
|
List Price£º$ 0.00 |
Your Price£º$ 9,600.00 |
|
|
|
|
Description
|
Specifications
|
Ordering Information
|
Condition and warranty
|
|
|
|
Features: ¡ñ Rugged construction providing shock, dust and moisture resistance ¡ñ Dual monitor position with automatic image orientation ¡ñ Automatic arc calibration and fi ber identifi cation ¡ñ User-selectable fi ber clamping method - sheath clamp or fi ber holders ¡ñ Auto-start tube heater feature ¡ñ Color LCD display with anti-refl ective coating for excellent visibility in bright sunlight ¡ñ Simultaneous battery charge and splicer operation Fonsun Technology ¡ñ Long life battery (up to 160 splice/heat cycles per charge) ¡ñ Detachable work table incorporated into the transit case ¡ñ Data and video download software included; software upgrade available via the internet ¡ñ Green friendly-RoHS & WEEE compliant
|
|
|
Specifications:
Applicable Fibers |
SM(ITU-T G.652), MM (ITU-T G.651), DS (ITU -T G.653), NZDS (ITU-T G.655) and other single mode fiber including ITU-T G.657 fiber |
Fiber count |
Single |
Applicable fiber dimensions |
Cladding Diameter: 80¦Ìm to150¦Ìm Coating Diameter:100¦Ìm to 1,000¦Ìm |
Fiber setting and cleaved length |
Sheathe clamp A (standard) : For coating dia. up to 250um (8 to 16mm cleave), coating dia. Of over 250um (16um cleaver) Sheathe clamp B (option) :For coating dia. up to 1000um (8 to 16mm cleave) Sheathe clamp C (option) :For 900um dia. Loose tube fiber (8 to 16mm cleave) Fiber holder (option) :FH-60-250 and FH-60-900 (10mm cleaver) |
Splicing Modes |
100 preset and user programmable modes |
Typical Average Splice Loss |
0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS (Measured by cut-back method relevant to ITU-T and IEC standards) |
Return loss |
£¾£¾60dB |
Splicing Time |
Typical 9 sec. with SM FAST, 10sec. with SM AUTO and 13sec with AUTO modes with standard SM (ITU-T G.652) |
Splice Loss Estimate |
Available |
Attenuation splicer function |
Intentional high splice loss of 0.1dB to 15dB (0.1dB step) can be made for an in-line fixed attenuator |
Tube heater / Heating Time |
Built-in tube heater with 30 heating modes.Typical 30 seconds with FP-03 sleeve, |
Applicable Protection Sleeve |
60mm, 40mm and Fujikura FPS01 series. |
Storage of Splice Result |
The last 2000 results to be stored in the internal memory |
Tension Test |
1.96 to 2.25N |
Operating Condition |
0 to 5,000m above sea level, 0 to 95%RH and -10 to 50 degC and up to 15m/s wind velocity, respectively |
Storage Condition |
0 to 95%RH and -40 to 80 degC respectively. Battery:-20 to 30 degC for long term |
Dimensions |
136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches) |
Weight |
2.3 kg (5.1 lbs) with AC adapter ADC-13; 2.7kg with BTR-08 |
Viewing Method |
Two CMOS cameras and 4.1 inch TFT color LCD monitor |
Fiber view and Magnification |
300X for single X or Y view, or 187X for X and Y view |
Power Supply |
Applicable voltage from 100 to 240V AC or 10 to 15V DC with ADC-13, 13.2V DC with BTR-08 battery |
No.of Splice Cycles with battery |
Typical 160 cycles (splice / tube heat) with BTR-08 |
Electrode life |
2500 arc-discharges |
Terminals |
USB 1.1 (Mini-B type) connector for PC communication. 6-pin Mini-DIN connector for HJS-02/03 or SH-8 power supply |
|
|
|
Ordering Information
DESCRIPTION |
PART # |
FSM-60S Fusion Splicer (machine only) Includes: ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair), Sheath Clamp,USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual,JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap ,Fonsun Technology |
S014531 |
FSM-60S Fusion Splicer Kit (with cleaver) Includes: CT30A Cleaver, ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair),Sheath Clamp, USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual, JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap |
S014532 |
FSM-60S Fusion Splicer Kit (with cleaver, battery and cord) Includes: BTR-08 Battery, DCC-14 Battery Charge Cord, CT-30A Cleaver, ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair), Sheath Clamp, USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual, JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap |
S014562 |
Accessories Recommended for the FSM-60S
DESCRIPTION |
PART # |
Cleavers |
|
CT-30A Cleaver |
S014080 |
Fiber Holders (pairs) |
|
FH-60-250 Fiber Holder |
S014548 |
FH-60-900 Fiber Holder |
S014549 |
Batteries and Power Cords |
|
ADC-13 AC Adapter |
S014535 |
BTR-08 Battery (160 splice/heat cycles) |
S014540 |
DCC-14 Power Cord (connects ADC-13 to BTR-08) |
S014541 |
DCC-12 Power Cord (connects ADC-13 to cigarette lighter socket) |
S013552 |
DCC-13 Power Cord (connects ADC-13 to power source via alligator clips) |
S013556 |
Miscellaneous |
|
ELCT2-20A Electrodes |
S013532 |
ASW-02 Splicing Workstation |
S010532 |
JP-05 Splice Sleeve Cooling Tray |
S014537 |
CLAMP-S60A Sheath Clamp (8mm min. cleave for 250um, 16mm min. cleave for 900um) |
S014550 |
CLAMP-S60B Sheath Clamp (8mm min. cleave for 250um and 900um) |
S014551 |
CLAMP-S60 Sheath Clamp (for 900um loose tube fiber) |
S014552 |
CC-24-60S Transit Case (fits only FSM-60S) |
S014559 |
One Year Extended Warranty |
S012996 |
Two Year Extended Warranty |
S013000 |
|
|
|
|
|
|
|
|
|